Water Facility Fragilities for INA

PGD/PGA

  • On Ground Concrete Tank (PW_PSTGC_PGA)

  • On Ground Wood Tank (PW_PSTGW_BKP_PGD)

  • On Ground Concrete Tank (PW_PSTGC_PGD)

  • On Ground Wood Tank (PW_PSTGW_BKP_PGA)

  • On Ground Steel Tank (PW_PSTGS_PGA)

  • On Ground Steel Tank (PW_PSTGS_BKP_PGA)

  • On Ground Steel Tank (PW_PSTGS_BKP_PGD)

  • On Ground Steel Tank (PW_PSTGS_PGD)

  • Wells (PW_PWE_PGA)

  • Small WTP ( < 50 MGD ) (PW_PWTS_BKP_PGD)

  • Wells (PW_PWE_PGD)

  • Small WTP ( < 50 MGD ) (PW_PWTS_BKP_PGA)

  • Above Ground Steel Tank (PW_PSTAS_PGA)

  • Default Facility (PW_PDFLT_PGA)

  • Medium Pumping Plant ( 10 to 50 MGD ) (PW_PPPM_PGD)

  • Medium Pumping Plant ( 10 to 50 MGD ) (PW_PPPM_PGA)

  • Above Ground Steel Tank (PW_PSTAS_PGD)

  • Above Ground Steel Tank (PW_PSTAS_BKP_PGA)

  • Wells (PW_PWE_BKP_PGA)

  • Large WTP ( > 200 MGD ) (PW_PWTL_BKP_PGD)

  • Large WTP ( > 200 MGD ) (PW_PWTL_BKP_PGA)

  • Default Facility (PW_PDFLT_PGD)

  • Wells (PW_PWE_BKP_PGD)

  • Buried Concrete Tank (PW_PSTBC_PGA)

  • Buried Concrete Tank (PW_PSTBC_BKP_PGD)

  • On Ground Concrete Tank (PW_PSTGC_BKP_PGD)

  • On Ground Concrete Tank (PW_PSTGC_BKP_PGA)

  • Large Pumping Plant ( > 50 MGD ) (PW_PPPL_PGD)

  • Large Pumping Plant ( > 50 MGD ) (PW_PPPL_BKP_PGD)

  • Large Pumping Plant ( > 50 MGD ) (PW_PPPL_BKP_PGA)

  • Buried Concrete Tank (PW_PSTBC_PGD)

  • Above Ground Steel Tank (PW_PSTAS_BKP_PGD)

  • Medium WTP ( 50-200 MGD ) (PW_PWTM_PGD)

  • Medium WTP ( 50-200 MGD ) (PW_PWTM_PGA)

  • Buried Concrete Tank (PW_PSTBC_BKP_PGA)

  • Medium Pumping Plant ( 10 to 50 MGD ) (PW_PPPM_BKP_PGA)

  • Small WTP ( < 50 MGD ) (PW_PWTS_PGD)

  • Small Pumping Plant ( < 10 MGD ) (PW_PPPS_BKP_PGA)

  • Medium Pumping Plant ( 10 to 50 MGD ) (PW_PPPM_BKP_PGD)

  • Small WTP ( < 50 MGD ) (PW_PWTS_PGA)

  • Large WTP ( > 200 MGD ) (PW_PWTL_PGA)

  • Large WTP ( > 200 MGD ) (PW_PWTL_PGD)

  • Small Pumping Plant ( < 10 MGD ) (PW_PPPS_PGA)

  • Medium WTP ( 50-200 MGD ) (PW_PWTM_BKP_PGA)

  • Medium WTP ( 50-200 MGD ) (PW_PWTM_BKP_PGD)

  • Large Pumping Plant ( > 50 MGD ) (PW_PPPL_PGA)

  • On Ground Wood Tank (PW_PSTGW_PGA)

  • Small Pumping Plant ( < 10 MGD ) (PW_PPPS_BKP_PGD)

  • Small Pumping Plant ( < 10 MGD ) (PW_PPPS_PGD)

  • On Ground Wood Tank (PW_PSTGW_PGD)

Hazus Buried Pipeline Fragilities

ductilePipelinePGD

Honegger and Eguchi (1992)

  • Buried Pipeline-1.0

brittlePipelinePGV

O'Rourke, M and Ayala (1993)

  • Buried Pipeline-1.0

brittlePipelinePGD

Honegger and Eguchi (1992)

  • Buried Pipeline-1.0

ductilePipelinePGV

O'Rourke, M and Ayala (1993)

  • Buried Pipeline-1.0

Buried Pipeline Fragilities

Buried Pipeline

Eidinger (2004)

  • Buried Pipeline (Concrete/Steel-RubberGasket)

Cast-Iron Pipe

O'Rourke, T and Jeon (1999)

  • Cast-Iron Pipe

Buried Pipeline

Eidinger (2004)

  • Buried Pipeline (Concrete/Steel-Lap)

Ductile-Iron Pipe

O'Rourke, T and Jeon (1999)

  • Ductile-Iron Pipe

Buried Pipeline

Eidinger (2004)

  • Buried Pipeline (Concrete/Steel-RubberGasket)

Buried Pipeline

Eidinger (2004)

  • Buried Pipeline (AsbestosCement-RubberGasket)

Asbestos-Cement Pipe

O'Rourke, T and Jeon (1999)

  • Asbestos-Cement Pipe (1994)

Asbestos-Cement Pipe

O'Rourke, T and Jeon (1999)

  • Asbestos-Cement Pipe

Buried Pipeline

Eidinger (2004)

  • Buried Pipeline (AsbestosCement-Cement)

Buried Pipeline

Eidinger (2004)

  • Buried Pipeline (WeldedSteel-Screwed)

Buried Pipeline

Eidinger (2004)

  • Buried Pipeline (WeldedSteel-Riveted)

Buried Pipeline

Eidinger (2004)

  • Buried Pipeline (WeldedSteel-Lap-All-Large)

Buried Pipeline

Eidinger (2004)

  • Buried Pipeline (WeldedSteel-RubberGasket)

Buried Pipeline

Eidinger (2004)

  • Buried Pipeline (Ductile Iron)

Buried Pipeline

O'Rourke, M and Ayala (1993)

  • Buried Pipeline-0.3

Buried Pipeline

Eidinger (2004)

  • Buried Pipeline (PVC)

Buried Pipeline

O'Rourke, M and Ayala (1993)

  • Buried Pipeline-1.0

Buried Pipeline

Eidinger (2004)

  • Buried Pipeline (WeldedSteel-Lap-NonCorrosive)

Buried Pipeline

Eidinger (2004)

  • Buried Pipeline (CastIron-RubberGasket-All)

Buried Pipeline

Eidinger (2004)

  • Buried Pipeline (CastIron-Cement-NonCorrosive)

Buried Pipeline

Eidinger (2004)

  • Buried Pipeline (CastIron-Cement-Corrosive)

Buried Pipeline

Eidinger (2004)

  • Buried Pipeline (CastIron-Cement-All)

Buried Pipeline

Eidinger (2004)

  • Buried Pipeline (WeldedSteel-Lap-Corrosive)

Buried Pipeline

Eidinger (2004)

  • Buried Pipeline (WeldedSteel-Lap-All)

 

Water Tank Fragilities

PGA

Eidinger

  • MidFill_AN46
  • N_531
  • HighFill_N209
  • LowFill_N95
  • Full_N120
  • MidFill_N251
  • MidFill_UN205

O'Rourke

  • HD_Low
  • HD_High
  • HighFill
  • AllTanks

 

Fragility Files on Ergo in XML

Potable Water Facility Fragilities for INA.xmlWater Tank Fragilities.xmlBuried Pipeline Fragilities.xmlHazus Buried Pipeline Fragilities.xml

 

  • No labels