When tried to publish the processed data

  • variable called TAU was all zero... (old variable, not being used... -9999)
  • 2008 and 2009 radiation value (incoming shortwave radiation was too high like 20%
  • PAR (photosynthetically active radiation)
  • AmeriFlux suggested linear correction.... Adjust and resubmit
  • can we get the radiation data from somewhere in the campus??