- Running EddyPro GUI Error -
Fatal error(20)> Encountered while interpreting a timestamp template.
Fatal error(20)> It may apply to retrieval of timestamps from the "Raw file name format"
Fatal error(20)> or the biomet or dynamic metadata records."
Fatal error(20)> Program execution aborted.
- Change TS to yyyy-mm-dd HH:MM
- Comparison of format.py output and Formatted Master Met data output sent by Katie.
- Formatted Master Met data has NAN and not -9999.0.
- PyFluxPro needs NAN as fill values. All -9999.0 should be changed to NAN.
- Formatted Master Met data has NAN and not -9999.0.
- Number of decimal places for numerical values in the output file of format.py
- No prob as of now.
- U_Avg and V_Avg fields have no units in raw met file. These 2 blank cells are populated with -9999.0 after format.py
- The fill value is correct.
- Bethany will check the units for these 2 variables.
- Is -9999.0 to be inputted as an int or string?
- Should be an int.
- Should all values be converted to numerical?
- Should be in numbers. However, EddyPro reads inputs as of now (string)
- Variables like MoistureA_Avg in output file coz the met variable key is absent in soil key.xlsx sheet.
- Not used in EddyPro and PyFluxPro. Can be absent in the formatted met data file.
- WindSpeed and WindDir - even if these fields are present in 'output_eddypro.csv' file for 2021, these fields will be ignored and EddyPro reads these variables from ghg file. Hence no need to drop these columns. Correct?
- That is correct.
- Function to check for required fields -
- what are the required fields in 'output_eddypro.csv' file. – multiple columns for soil temp and soil moisture - how to check for n number of columns?
- Global radiation, SWin, - from settings in EddyPro. – check the dataset if these variables are present in the dataframe.
- What are the required fields in ghg file? How to test for the same?
- Do not check for anything in ghg file
- what are the required fields in 'output_eddypro.csv' file. – multiple columns for soil temp and soil moisture - how to check for n number of columns?
- What should be done if there are missing timestamps in precip data?
...