Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

Field NameField DescriptionField TypeAcceptable ValuesInformational
IDUnique numeric identifier in the fragility datasetInteger N/ANo
Fragility ID CodeUnique key for each fragility (e.g. SF_C1_1 for structural fragility for C1 structure type)String N/ANo
AuthorIdentifies the person(s) who provided each fragility set.String N/AYes
Structure TypeStructure Type this fragility curve is designed forString N/AYes
StoriesIdentifies the number of stories used for the model building when constructing fragilities. .IntegerA value of “0” indicates multiple story levels were considered (for fragility surfaces)Yes
DescriptionA textual description providing information about the derivation of this fragility curve setString N/AYes
Ground MotionsGround motion records used for time-history analyses when constructing fragilitiesString N/AYes
CodeDesign code for the fragility setString Yes
Damage TypeThe type of damage type this fragility representsString Structural, Non-StructuralYes
Demand TypeThe demand type required by the fragility, can include the period if applicable (e.g. 0.2 Sa )String PGA, PGV, PGD, Sa, Sd, SvNo
Demand UnitThe units of the demand typeString g, %g, etcNo
Limit StatesThe limit states which define the transitions between damage states for each fragility set.String 3 limit states with a colon delimiter (e.g. Moderate: Extensive: Complete)No
T Eqn TypeEquation to estimate the natural period of a building.Integer 1, 2, or 3 (see technical manual)No
Frag Eqn TypeFragility equation type.Double

1 - Lognormal distribution, 2 - Normal Distribution

 No
ParametersThe number of fragility parameters (e.g. 6 if three curves with median and beta), 18 if a surface.Integer N/A

No

 