Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

(error) Need datalogger installation Still in process of installation 
SourceDescriptionHistoricalCuratorExternalStatusLinksIssues
HOBO

Big Ditch, Camp Creek, Goose Creek, Goose Creek at Bucks Pond, Saybrook, Wildcat

An additional stream was created for Goose Creek at Bucks Pond and Saybrook. These two locations have air sensors and water sensors, and a calculation is performed from these two measurements that determines the water elevation.

 Mingjing YuNo(tick) Ingestedhttp://imlczo.ncsa.illinois.edu/...

 

 



Eddy Flux TowerClear Creek 1-1, 2-1 Christopher Wilson No(error) Have location, need dataSee attached spreadsheetThere are two sites that light up for CCW-Z2-S1-EF1.  The other one should be CCW-Z1-S1-EF1. 
Soil gas AnalyzerClear Creek 1-1, 1-2, 2-1, 3-1  (question)No(error) Have location, need dataSee attached spreadsheet

Part of ER experiments, still being processed for publication.

 

Rainfall SimulatorsClear Creek 1-1, 2-1 (question)No(error) Have location, need data 

Part of ER experiments, still being processed for publication.

Water Content Reflectrometer

Clear Creek 1-1, 2-1 (question)No(error) Have location, need data 

Part of ER experiments, still being processed for publication.

H
USGS Water Quality

Historical data ingested by Ye Fan. Not currently being updated.

 

2/2014-5/2014Ye FanYes(tick) Ingested  
IFC River SensorsCLRCRK01, CLRCRK03, CLRCRKS01, CLRCRKS02, CLRCRKW01 (question)Yes(tick) Ingestedhttp://ifis.iowafloodcenter.org/ifis/en/ 
Sangamon Forest Preserve site
Latitude:  40.281513°
Longitude: -88.355564° (approximate, from Google Earth)
Parameters: Rainfall (mm),
Relative Humidity,
Solar Radiation (w/m2),
windspeed (m/s),
wind direction (degrees),
Air temperature (deg C),
Leaf wetness (1=wet/2=not wet). 
All parameters recorded at 1 minute interval.
 Allison GoodwellNo(tick) Ingested 

 

  1. It is taking forever for the data to load
Flux Tower

Latitude: 40.15569444°

Longitude: -88.55511111°

Parameters: 25m tower. Instruments located at 3 heights: 25m, 10m, ground level. Infrared Temperature, Heat Flux, NDVI, PRI, Soil moisture/EC/Soil Temp, Wind speed, Photon Flux, CO2/H2O Flux, Radiation Flux

 Josh PeschelNo

(tick) Have Installation

(tick) Data Logger Installed

 

(tick) Data is

not sending from the Campbell Datalogger

being uploaded to the IMLCZO server and then uploaded to Clowder.

(error) Datapoints Parser is in progress.

Allerton Trust Farm

Latitude:40.025611°

Longitude: -88.661167° (approximate from Google Earth)

Parameters: This site is equipped with an ISCO to collect data from tile drains. Soil Moisture/Soil Temp/Soil EC, Water EC/Water Temp/Water Depth, Wind speed, Precipitation, Air Temp/Vapor Pressure/Relative Humidity, ISCO

 Don Keefer/Derek Wagner/Dongkook WooNo

(tick)Installation occurred

 

Decagon Datalogger : http://www.ech2o.com/ 
Username: 5G0F5179
Password: shwai-regi
Campbell Datalogger:
Installed

(tick) Campbell Scientific data is being uploaded to IMLCZO server and then uploaded to Clowder.

(error) Campbell Scientific Datapoints Parser is in progress.

(error) Decagon has provided access to the API and Brock is working on the uploader to Clowder. Questions still remain regarding the precision Decagon uses when converting the raw data. Waiting to hear back from them before creating datapoints.

Ameriflux Bondville

Historical data from Aug-1996 - 12/31/2008.

 

1996-2008Brock AngeloYes(tick) Ingested

Ameriflux Bondville Data

  1. The data is not located flux tower according
Illinois State Water Survey (ISWS)Several historical sensors ingested. As of 2015, only ISWS105 at Mahomet and ISWS134 at Saybrook are being updated. These are added to a Samba share and are parsed hourly and added to the API. 

Erin Bauer  

ebauer@illinois.edu

No(tick) Ingested  
Illinois State Water Survey (ISWS)

Three locations of suspended sediment concentration collection through an ISCO

Saybrook (40.437162°, -88.554961°)

Mahomet (40.171096°, -88.446063°) 

Monticello (40.030936°, -88.588422°)

All three locations use a 6712 Teledyne ISCO to collect samples. Also included are:

Saybrook- CR850 datalogger, CS451 pressure transducer

Mahomet- CR10X datalogger, CS475 water level indicator

Monticello- 1640 liquid level actuator

 Laura Keefer, Bruce RhoadsNo

(error) Have Location,

Need Data

  
Illinois State Geological Survey (ISGS)

The fiber-optic distributed temperature sensing (FO-DTS) team at the ISGS is equipped with: 

1. SensorNet Oryx+ Distributed Temperature Sensing (DTS) system [Travel in Truck]

2. Fujikura FS70 Fusion Splicer [Travel in Truck]

3. Brugg BRUsens Temperature 4-fiber cable: 1100m for in situ measurement [Travel in Truck]

4. MULTILINK AT-RK28T7X-004 2-fiber cable: 2500m for ditch bed deployment at flux tower site in 2015-2016 (40.15569444°, -88.55511111°)

5. AFL DNS-0763 Flat Drop 2-fiber cable: 104m for 40m well in Rantoul site (40.282582°, -88.193135°)

6. AFL DNS-0763 Flat Drop 2-fiber cable: 171m for 100m borehole in Rantoul site  (40.282582°, -88.193135°)

7. AFL DNS-0763 Flat Drop 2-fiber cable: 1100m for in situ measurement [Travel in Truck]

 8. AFL DNS-0763 Flat Drop 2-fiber cable: 325m experimental configuration for future deployment 

 

 9. One 240 volt and 2,000 watt cartridge heater with 100m cable is under construction at the ISGS for future heat tracer tests such fracture detection and groundwater/surface water interaction.

 Yu-Feng LinNo

(error) Have Location,

Need Data

  

...