      When opening the style editor, if the user changes the editor to interval style from other styles like ramp or unique, the values in the editor should be reset. For example, in raster dataset, if the current map style is ranged (ramp) style, when the user opens the style editor to change the style, the editor is set to ranged since the current style is ranged. If the user tries to change the style to interval, the range values from the ramp will automatically transfer to the interval values. In this case, if these values are applied, the highest value will not be drawn in the map since the ramp is 'equal and less than' condition, but interval is 'less than'. To avoid this issue, when the map type changes, the values should be rest.